Please enable javascript for full website functionality.

Memmert Peltier Cooled Incubators

Overview

IPP30 Plus

IPP30 Plus Memmert Peltier-cooled incubators guarantee the perfect climate and temperature for laboratory applications. 

Contact us for customization options and pricing.

Features

Stainless Steel Scratch resistant, hygienic and durable.
AtmoCONTROL Create & monitor programs.
3 Year Warranty A limited 3 year warranty is included with the option to purchase an extra year.
TwinDISPLAY Twice the features of SingleDISPLAY. Monitor programs easily via Ethernet or USB.

Temperature & Humidity

Control technology

Safety, Standards, & Data

Interior & Exterior

Accessories

Temperature & Humidity

Temperature Specs:

  • Working temperature range without humidity: 
    From 0°C (at least 20°C below ambient) to 70°C
  • Setting accuracy temperature: 
    0.1°C
  • Temperature:
    2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value

Heating Concept:

  • Peltier:
    Energy-saving Peltier heating-/cooling system integrated in the rear (heat pump principle)
  • Peltier:
    Heating and cooling performance distribution by individual control of the Peltier elements in the upper and lower row

Control technology

Control Technology:

  • Adjustable parameters: 
    Temperature (Celcius or Fahrenheit), program time, time zones, daylight savings time
  • Function SetpointWAIT: 
    The process time does not start until the set temperature is reached
  • Language setting:
    German/English/Spanish/French
  • Calibration:
    Three freely selectable temperature values

Safety & Standards

Safety:

  • Alarm: 
    Audible and visual
  • Temperature control: 
    Over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB protection class 2 selection on display
  • AutoSAFETY:
    additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature
  • Autodiagnostic system:
    For fault analysis

Additional data

Electrical data

115 Volts
  • (+/- 10%)
  • 50/60 Hz / approx. 1.4 amps
230 Volts
  • (+/- 10%)
  • 50/60 Hz / approx. 0.7 amps

Certifications

CE Mark of European Economic Area EAC CertifiedVDE certifiedCUL Certified

Interior & Exterior

Stainless Steel Interior

  • Volume:
    Approx. 1.1 ft³/32 L
  • Dimensions W x H x D in mm
    w(A) x h(B) x d(C): 400 x 320 x 250 mm
  • Number of Stainless Steel Grids: 
    1
  • Max. number of grids: 
    3
  • Max. loading per grid: 
    20 kgs / 44 lbs.
  • Max. loading of chamber: 
    60 kgs / 132 lbs.

Textured Stainless Steel Exterior

  • Dimensions: 
    w x h x d : 585 x 707 x 524 mm

Stainless Steel

For many years exterior textured stainless steel has been the unmistakable feature of Memmert ovens, incubators, and climate chambers in laboratory and light-industrial settings. Memmert equipment exemplifies functional design in its most elegant and hygienic form, while still being scratch resistant, robust and durable.

Stainless steel is the ideal material for temperature control chambers and heating baths. It is particularly corrosion-resistant, hygienic, robust and recyclable without question.

Wherever Memmert ovens and heating baths are used, the superiority of high-quality stainless steel is undeniable in comparison to others that utilize coated sheet steel, which can corrode very quickly when in constant use.

For the outer housing of all Memmert appliances, textured stainless steel is used (rear walls are zinc-plated sheets). The inner chamber, sliding shelves/grids, housing, interior basin and accessories for every heating bath, stainless steel of class W-St. 1.4301 (ASTM 304) is used. Since aggressive substances are frequently used in the vacuum drying oven, the inner chamber and thermoshelves are made of stainless-steel W-St. 1.4404 (ASTM 316L), and the tubing is made of stainless-steel W-St. 1.4571 (ASTM 316i).

Accessories

 

Model sizes3055110260410750106014002200
Stainless steel grids, electropolished E28884 E20164 E20165 E28891 E28891 E20182 B41251 B38955 B38955
Reinforced stainless steel grid, max. loading 60 kg (size 750 with guide bars and fixing screws and only in connection with option K1). Please consider max. loading of chamber. - - E29767 E29766 E29766 B32190 B32550 - -
Perforated stainless steel shelf B29727 B03916 B00325 B29725 B29725 B00328 - - -
Perforated stainless steel shelf B29727 B03916 B00325 B29725 B29725 B00328 - - -
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1. Please consider max. loading of chamber - - - - - B32191 B32549 - -
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02070 E02072 E02073 E29726 E29726 E02075 B32599 - -
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 - - - - - B34055 - - -
Max. loading per slide-in drip tray (kg) 1,5 1,5 3 4 4 8 8 - -
Max. loading per bottom drip tray (kg) 1,5 1,5 3 4 4 8 8 - -
Guarantee extension by 1 year GA1Q5 GA1Q5 GA1Q5 GA2Q5 GA2Q5 GA2Q5 GA4Q5 GA4Q5 GA4Q5
USB-Ethernet adapter E06192 E06192 E06192 E06192 E06192 E06192 E06192 E06192 E06192
Ethernet connection cable 5 m for computer interface E06189 E06189 E06189 E06189 E06189 E06189 E06189 E06189 E06189
Ethernet connection cable 5 m for computer interface E06189 E06189 E06189 E06189 E06189 E06189 E06189 E06189 E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170 B33170 B33170 B33170 B33170 B33170 B33170 B33170 B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) B33172 B33172 B33172 B33172 B33172 B33172 B33172 B33172 B33172
Set of height adjustable feet (4 pcs) B29768 B29768 B29768 B29768 - - - - -
Stacking set (4 pcs) for stacking of appliances of same size B29744 B29744 B29744 - - - - - -
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29728 B29730 B29734 B29738 B42116 B29742 B29742 - -
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29729 B29731 B29735 B29739 B42117 B29643 B29643 - -
Subframe, adjustable in height (size 30 and 55: height 600 mm, size 110 and 260: height 500 mm) B29745 B29747 B29749 B29751 - - - - -
Subframe, on castors (size 30 and 55: height 660 mm, size 110: height 560 mm) B29746 B29748 B29750 - - - - - -
Subframe, adjustable in height (height 130 mm, for example for units with fresh-air filter) B33657 B33659 B33661 B33664 - - - - -
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPP, ICH L, IPPplus) B04713 B04713 B04713 B04713 B04713 B04713 - - -
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) B04714 B04714 B04714 B04714 B04714 B04714 B04714 B04714 B04714
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696 E39696 E39696 E39696 E39696 E39696 E39696 E39696 E39696
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39697 E39697 E39697 E39697 E39697 E39697 E39697 E39697 E39697
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124 D00124 D00124 D00124 D00124 D00124 D00124 D00124 D00124
IQ/OQ document with device-specific works test data for one free-selectable temperature value, incl. temperature distribution survey at Memmert for 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060, 2200) and 26 measuring points (size 1400) according to DIN 12880:2007-05. PQ check list as support for validation by customer. D00125 D00127 D00127 D00127 D00127 D00127 D00127 D00127 D00127
On-site IQ/OQ for a freely selectable temperature value, including temperature distribution survey for 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060, 2200) and 26 measuring points (size 1400) to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100
Extension of DLQ100 by an additional freely selectable temperature value (not subject to discount) DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A
Individual on-site Performance Qualification (PQ) DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200
Maintenance IPP/ IPPeco - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) S00317 S00317 S00317 S00317 S00317 S00317 S00317 S00317 S00317
Maintenance contract IPP/ IPPeco - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) S00317J S00317J S00317J S00317J S00317J S00317J S00317J S00317J S00317J
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, FR only) S00205 S00205 S00205 S00205 S00205 S00205 S00205 S00205 S00205
Calibration of an additional temperature value (not subject to discount) S00215 S00215 S00215 S00215 S00215 S00215 S00215 S00215 S00215

 

Introducing Peltier App

Redefining Energy Efficiency in Equipment Temperature Control!

Experience Efficiency Now

Individual Customizations for Specialized Applications


With Memmert m360 we are able to customize our equipment from small modifications to high-tech innovations to meet your exact requirements.

Learn more about m360

Connect With Your
Regional Salesperson

VERSATILE PRODUCTS TO SERVE DEMANDING APPLICATIONS

Medical

Industrial

Electronics

Aerospace

Education

Life Science

Pharmaceuticals

Food & Beverage

Companies Served

atmocontrol instagram pdf techsupport touch twindisplay twitter phone email youtube linkedin play stainless facebook warranty mappin operation