ICH260 Memmert Stability Climate Chambers
Former Models: ICH260 ICH600
Overview
ICH 260 Memmert stability climate chambers guarantee the perfect atmosphere for climate and temperature tests.
Contact us for customization options and pricing.
Features
Temperature & Humidity
Control technology
Safety, Standards, & Data
Interior & Exterior
Accessories
Temperature & Humidity
Temperature Specs:
- Working temperature range without humidity:
-10°C up to 60°C - Working temperature range with humidity:
10 to 60°C - Setting accuracy temperature:
0.1°C - Temperature:
2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
Humidity Specs:
- Humidity:
Humidity supply with distilled water from external tank by self-priming pump - Humidification:
Humidification by hot steam generator - Humidity:
Active humidifying and de-humidifying adjustable from 10-80 % rh with digital display of relative humidity – resolution of display 0.1 %, setting accuracy 0.5 %
Control technology
Control Technology:
- ControlCOCKPIT:
TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays. - Language Setting:
German, English, Spanish, French, Polish, Czech, Hungarian - Adjustable Parameter:
Temperature (Celsius or Fahrenheit), relative humidity, program time, time zones, daylight savings time - Timer:
Digital backwards counter with target time setting, adjustable from 1 minute to 99 days - Function SetpointWAIT:
The process time does not start until the set temperature is reached - Calibration:
Three freely selectable values each, temperature/humidity/CO2
Safety & Standards
Safety:
- Temperature control:
mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature - Temperature control:
over- and under temperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, adjustable at the controller - AutoSAFETY:
additionally integrated over- and under temperature protection “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or under temperature, heating is switched off in case of overtemperature, the compressor in case of under temperature - Autodiagnostic system:
integral fault diagnostics for temperature and humidity control - Alarm:
with visual and acoustic alarm in case of over-/under temperature and under humidity, open door and empty water tank
Additional data
Electrical data
230 Volts
- 50 Hz / approx. 1350 W
Certifications
Interior & Exterior
Stainless Steel Interior
- Volume:
256 l - Dimensions W x H x D in mm
w(A) x h(B) x d(C): 640 x 800 x 500 mm - Max. number of internals:
9 - Max. loading of chamber:
200 kgs - Max. loading per internal:
20 kgs
Textured Stainless Steel Casing
- Dimensions:
w x h x d : 824 x 1552 x 734 mm - Housing:
rear zinc-plated steel - Installation:
on lockable castors
Stainless Steel
For many years exterior textured stainless steel has been the unmistakable feature of Memmert ovens, incubators, and climate chambers in laboratory and light-industrial settings. Memmert equipment exemplifies functional design in its most elegant and hygienic form, while still being scratch resistant, robust and durable.
Stainless steel is the ideal material for temperature control chambers and heating baths. It is particularly corrosion-resistant, hygienic, robust and recyclable without question.
Wherever Memmert ovens and heating baths are used, the superiority of high-quality stainless steel is undeniable in comparison to others that utilize coated sheet steel, which can corrode very quickly when in constant use.
For the outer housing of all Memmert appliances, textured stainless steel is used (rear walls are zinc-plated sheets). The inner chamber, sliding shelves/grids, housing, interior basin and accessories for every heating bath, stainless steel of class W-St. 1.4301 (ASTM 304) is used. Since aggressive substances are frequently used in the vacuum drying oven, the inner chamber and thermoshelves are made of stainless-steel W-St. 1.4404 (ASTM 316L), and the tubing is made of stainless-steel W-St. 1.4571 (ASTM 316i).
Accessories
Model sizes | 110 | 110 eco | 260 | 260 eco | 750 | 750 eco |
---|---|---|---|---|---|---|
Stainless steel grids, electropolished | E20165 | E20165 | E28891 | E28891 | E20182 | E20182 |
Reinforced stainless steel grid, electropolished, max. loading 60 kg (model 750 with guide bars and fixing screws and only in connection with option K1) | E29767 | E29767 | E29766 | E29766 | B32190 | B32190 |
Perforated stainless steel shelves | B00325 | B00325 | B29725 | B29725 | B00328 | B00328 |
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1. Please consider max. loading of chamber | - | - | - | - | B32191 | B32191 |
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 | E02073 | E02073 | E29726 | E29726 | E02075 | E02075 |
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 | - | - | - | - | B32763 | B32763 |
Max. loading per slide-in drip tray (kg) | 3 | 3 | 4 | 4 | 8 | 8 |
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 | B04359 | B04359 | B29722 | B29722 | B04362 | B04362 |
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 | - | - | - | - | B34055 | B34055 |
Max. loading per bottom drip tray (kg) | 3 | 3 | 4 | 4 | 8 | 8 |
Holder for water tank (2.5 litres) for mounting on the rear of the appliance. Standard equipment for size 750 | E32172 | E32172 | E32172 | E32172 | - | - |
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. | ZWVR6 | ZWVR6 | ZWVR6 | ZWVR6 | ZWVR6 | ZWVR6 |
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand | ZWVR7 | ZWVR7 | ZWVR7 | ZWVR7 | ZWVR7 | ZWVR7 |
CO2 pressure reducing valve to DIN 8546, incl. gas cylinder monitor (only ICH C) | E02087 | - | E02087 | - | E02087 | - |
USB-Ethernet adapter | E06192 | E06192 | E06192 | E06192 | E06192 | E06192 |
Ethernet connection cable 5 m for computer interface | E06189 | E06189 | E06189 | E06189 | E06189 | E06189 |
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) | B33170 | B33170 | B33170 | B33170 | B33170 | B33170 |
FDA conforming software AtmoCONTROL (FDA edition). Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) | FDAQ1 | FDAQ1 | FDAQ1 | FDAQ1 | FDAQ1 | FDAQ1 |
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) | FDAQ2 | FDAQ2 | FDAQ2 | FDAQ2 | FDAQ2 | FDAQ2 |
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPP, ICH L, IPPplus) | B04713 | B04713 | B04713 | B04713 | B04713 | B04713 |
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) | B04714 | B04714 | B04714 | B04714 | B04714 | B04714 |
DAkkS calibration for one (freely selectable) temperature and humidity value according to method C (DKD-R 5-7) | E48847 | E48847 | E48847 | E48847 | E48847 | E48847 |
DAkkS calibration for further temperature and humidity values according to method C (DKD-R 5-7) | E48848 | E48848 | E48848 | E48848 | E48848 | E48848 |
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer | D00124 | D00124 | D00124 | D00124 | D00124 | D00124 |
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer | D00127 | D00127 | D00127 | D00127 | D00127 | D00127 |
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring points (26 measuring points on model HPP1400) to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP and ICH). | D00136 | D00136 | D00136 | D00136 | D00136 | D00136 |
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, and measuring of light intensity, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models ICHeco L/ICH L). Price for validation at customer site on demand (GER, AT, CH only) | D00137 | D00137 | D00137 | D00137 | D00137 | D00137 |
IQ/OQ document with device-specific works test data for one free-selectable CO2, humidity and temperature value, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models ICH C). Price for further CO2, humidity and temperature values on demand | D38897 | - | D38897 | - | D38897 | - |
On-site IQ/OQ for a freely selectable temperature and humidity value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) | DLQ101 | DLQ101 | DLQ101 | DLQ101 | DLQ101 | DLQ101 |
Extension of DLQ101 by an additional freely selectable temperature and humidity value (not subject to discount) | DLQ101A | DLQ101A | DLQ101A | DLQ101A | DLQ101A | DLQ101A |
On-site IQ/OQ for a freely selectable temperature and CO2 value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (models ICH C) (excluding travel costs, not subject to discount, GER, AT, FR only) | DLQ102 | - | DLQ102 | - | DLQ102 | - |
Extension of DLQ102 by an additional freely selectable temperature and CO2 value (models ICH C) (not subject to discount) | DLQ102A | - | DLQ102A | - | DLQ102A | - |
On-site IQ/OQ for a freely selectable temperature, humidity and CO2 value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (models ICH C) (excluding travel costs, not subject to discount, GER, AT, FR only) | DLQ103 | - | DLQ103 | - | DLQ103 | - |
Extension of DLQ103 by an additional freely selectable temperature, humidity and CO2 value (requires option K7) (not subject to discount) | DLQ103A | - | DLQ103A | - | DLQ103A | - |
Individual on-site Performance Qualification (PQ) | DLQ200 | DLQ200 | DLQ200 | DLQ200 | DLQ200 | DLQ200 |
Maintenance ICH-C - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) | S00316 | - | S00316 | - | S00316 | - |
Maintenance contract ICH-C - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) | S00316J | - | S00316J | - | S00316J | - |
Maintenance ICH/ ICHeco - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) | S00322 | S00322 | S00322 | S00322 | S00322 | S00322 |
Maintenance contract ICH/ ICHeco - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) | S00322J | S00322J | S00322J | S00322J | S00322J | S00322J |
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, FR only) | S00205 | S00205 | S00205 | S00205 | S00205 | S00205 |
Calibration of an additional temperature value (not subject to discount) | S00215 | S00215 | S00215 | S00215 | S00215 | S00215 |
Calibration of one freely selectable temperature and humidity value (excluding travel costs, not subject to discount, GER, AT, FR only) | S00207 | S00207 | S00207 | S00207 | S00207 | S00207 |
Calibration of an additional temperature and humidity value (not subject to discount) | S00216 | S00216 | S00216 | S00216 | S00216 | S00216 |
Calibration of one freely selectable temperature and humidity value including CO2 (excluding travel costs, not subject to discount, GER, AT, FR only) | S00211 | - | S00211 | - | S00211 | - |
Calibration of an additional temperature and humidity value including CO2 (not subject to discount) | S00217 | - | S00217 | - | S00217 | - |
Individual Customizations for Specialized Applications
With Memmert m360 we are able to customize our equipment from small modifications to high-tech innovations to meet your exact requirements.