UF160TS Memmert Specialized Equipment
Overview
Universal Oven UF160TS
The Memmert heating oven with a fully insulated stainless steel door on both sides saves time during loading and reduces the risk of contamination, especially when handling sensitive load between grey and clean rooms. On this page, you can find all the essential technical data on our pass-through oven. Our customer relations team will be pleased to help if you want further information.
Contact us for customization options and pricing.
Features
Temperature & Humidity
Control technology
Safety, Standards, & Data
Interior & Exterior
Accessories
Temperature & Humidity
Temperature Specs:
- Temperature: 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
- Set temperature range: min.10°C above ambient up to +250°C
- Resolution of display for actual values: 0.1°C
Control technology
Control Technology:
- ControlCOCKPIT: adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays
- Language Setting: German, English, Spanish, French, Polish, Czech, and Hungarian
- Timer: Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
- Function HeatBALANCE: adapting the distribution of the heating performance of the upper and lower heating circuit from -50 % to +50 %
- Function SetpointWAIT: the process time does not start until the set temperature is reached
- Calibration: three freely selectable temperature values
Safety & Standards
Safety:
- Temperature control: independently working, digitally adjustable electronic micro-processor overtemperature monitor TWW, protection class 3.1 (max-value for overtemperature, min-value for undertemperature) and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature
- AutoSAFETY: additionally integrated over- and undertemperature protection "ASF", automatically following the
setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is
switched off in case of overtemperature - Auto diagnostic system: for fault analysis
Additional data
Electrical data
230 Volts
- (+ / - 10%)
- 50/60 Hz / 13.9 amps
Certifications
Interior & Exterior
Stainless Steel Interior:
- Volume: 161 l
- Dimensions: w(A) x h(B) x d(C): 22” x 28.3” x 15.7”
- Max. number of grids/shelves: 8
- Max. loading of chamber 463 lbs
- Max. loading per grid/shelf 44 lbs
Stainless Steel
For many years exterior textured stainless steel has been the unmistakable feature of Memmert ovens, incubators, and climate chambers in laboratory and light-industrial settings. Memmert equipment exemplifies functional design in its most elegant and hygienic form, while still being scratch resistant, robust and durable.
Stainless steel is the ideal material for temperature control chambers and heating baths. It is particularly corrosion-resistant, hygienic, robust and recyclable without question.
Wherever Memmert ovens and heating baths are used, the superiority of high-quality stainless steel is undeniable in comparison to others that utilize coated sheet steel, which can corrode very quickly when in constant use.
For the outer housing of all Memmert appliances, textured stainless steel is used (rear walls are zinc-plated sheets). The inner chamber, sliding shelves/grids, housing, interior basin and accessories for every heating bath, stainless steel of class W-St. 1.4301 (ASTM 304) is used. Since aggressive substances are frequently used in the vacuum drying oven, the inner chamber and thermoshelves are made of stainless-steel W-St. 1.4404 (ASTM 316L), and the tubing is made of stainless-steel W-St. 1.4571 (ASTM 316i).
Accessories
Model sizes | 160 | 260 | 450 | 750 |
---|---|---|---|---|
Additional reinforced stainless steel grid, electropolished, max. loading 60 kg; with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber | - | - | B32190 | B32190 |
Stainless steel grids, electropolished | E20165 | E28891 | E20182 | E20182 |
Perforated stainless steel shelf | B00325 | B29725 | B00328 | B00328 |
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1. Please consider max. loading of chamber | - | - | B32191 | B32191 |
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 | E02073 | B29726 | E02075 | E02075 |
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 | - | - | B32763 | B32763 |
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 | B04359 | B29722 | B04362 | B04362 |
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 | - | - | B34055 | B34055 |
Max. loading per slide-in drip tray (kg) | 3 | 4 | 8 | 8 |
Max. loading per bottom drip tray (kg) | 3 | 4 | 8 | 8 |
Flush-fit unit set (stainless steel frame covering gap between oven and wall opening), without air slots - technical clarification required | B33204 | B33205 | B33206 | B33207 |
Guarantee extension by 1 year | GA1Q5 | GA2Q5 | GA2Q5 | GA2Q5 |
USB-Ethernet adapter | E06192 | E06192 | E06192 | E06192 |
Ethernet connection cable 5 m for computer interface | E06189 | E06189 | E06189 | E06189 |
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) | B33170 | B33170 | B33170 | B33170 |
Set of height adjustable feet (4 pcs) | B29768 | B29768 | - | - |
FDA conforming software AtmoCONTROL (FDA edition). Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) | FDAQ1 | FDAQ1 | FDAQ1 | FDAQ1 |
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) | FDAQ2 | FDAQ2 | FDAQ2 | FDAQ2 |
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) | E39696 | E39696 | E39696 | E39696 |
DAkkS calibration for further temperature values according to method C (DKD-R 5-7) | E39697 | E39697 | E39697 | E39697 |
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer | D00124 | D00124 | D00124 | D00124 |
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer | D00127 | D00127 | D00127 | D00127 |
On-site IQ/OQ for a freely selectable temperature value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) | DLQ100 | DLQ100 | DLQ100 | DLQ100 |
Extension of DLQ100 by an additional freely selectable temperature value (not subject to discount) | DLQ100A | DLQ100A | DLQ100A | DLQ100A |
Individual on-site Performance Qualification (PQ) | DLQ200 | DLQ200 | DLQ200 | DLQ200 |
Maintenance UIS - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) | S00311 | S00311 | S00311 | S00311 |
Maintenance contract UIS - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) | S00311J | S00311J | S00311J | S00311J |
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, FR only) | S00205 | S00205 | S00205 | S00205 |
Calibration of an additional temperature value (not subject to discount) | S00215 | S00215 | S00215 | S00215 |
Individual Customizations for Specialized Applications
With Memmert m360 we are able to customize our equipment from small modifications to high-tech innovations to meet your exact requirements.