Memmert Compressor Cooled Incubators
Former Models: ICP600
Overview
ICP260
ICP 260 Memmert Compressor-cooled incubators guarantee the perfect climate and temperature for laboratory applications.
Contact us for customization options and pricing.
Features
Temperature & Humidity
Control technology
Safety, Standards, & Data
Interior & Exterior
Accessories
Temperature & Humidity
Temperature Specs:
- Working temperature range:
From -12°C up to 60°C (Optimum performance of cooling aggregate at an ambient temperature of 16°C up to 32°C. Not suitable for long-term storing at sub-zero temperatures. During permanent operation, the glass door may ice over.) - Setting accuracy temperature:
0.1°C - Temperature:
2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
Heating Concept:
- Air Jacket:
Air jacket heating system for gentle all-around heating - Heating concept:
No drying-up of the load caused by the cooling device due to separation of thermal jacket from interior - Cooling:
Energy-saving use of CFC-free cooling/heating system (refrigerant R134a) - Defrosting:
Highly efficient automatic defrosting system
Control technology
Control Technology:
- ControlCOCKPIT:
TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. - Language setting:
German, English, Spanish, French, Polish, Czech, Hungarian - Timer:
Digital backwards counter with target time setting, adjustable from 1 minute to 99 days - Function SetpointWAIT:
The process time does not start until the set temperature is reached - Calibration:
Three freely selectable temperature values - Adjustable parameters:
Temperature (Celsius or Fahrenheit), fan speed, programme time, time zones, summertime/wintertime
Safety & Standards
Safety:
- Temperature control:
Mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature - Temperature control:
Over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display - AutoSAFETY:
Additionally integrated over- and undertemperature protection “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature, compressor in case of undertemperature - Autodiagnostic system:
For fault analysis - Alarm:
Visual and acoustic.
Additional data
Electrical data
115 Volts
- (+/- 10%)
- 50/60 Hz / approx. 10.4 amps
230 Volts
- (+/- 10%)
- 50/60 Hz / approx. 5.0 amps
Certifications
Interior & Exterior
Stainless Steel Interior
- Volume:
256 I - Dimensions W x H x D in mm:
w(A) x h(B) x d(C): 640 x 800 x 500 mm - Max. loading of chamber:
200 kg - Max. loading per internal:
20 kg
Textured Stainless Steel Casing
- Dimensions:
w x h x d : 824 x 1552 x 684 mm - Installation:
On lockable castors - Housing:
Rear zinc-plated steel
Stainless Steel
For many years exterior textured stainless steel has been the unmistakable feature of Memmert ovens, incubators, and climate chambers in laboratory and light-industrial settings. Memmert equipment exemplifies functional design in its most elegant and hygienic form, while still being scratch resistant, robust and durable.
Stainless steel is the ideal material for temperature control chambers and heating baths. It is particularly corrosion-resistant, hygienic, robust and recyclable without question.
Wherever Memmert ovens and heating baths are used, the superiority of high-quality stainless steel is undeniable in comparison to others that utilize coated sheet steel, which can corrode very quickly when in constant use.
For the outer housing of all Memmert appliances, textured stainless steel is used (rear walls are zinc-plated sheets). The inner chamber, sliding shelves/grids, housing, interior basin and accessories for every heating bath, stainless steel of class W-St. 1.4301 (ASTM 304) is used. Since aggressive substances are frequently used in the vacuum drying oven, the inner chamber and thermoshelves are made of stainless-steel W-St. 1.4404 (ASTM 316L), and the tubing is made of stainless-steel W-St. 1.4571 (ASTM 316i).
Accessories
Model sizes | 110 | 110 eco | 260 | 260 eco | 450 | 450 eco | 750 | 750 eco |
---|---|---|---|---|---|---|---|---|
Stainless steel grids, electropolished | E20165 | E20165 | E28891 | E28891 | E20182 | E20182 | E20182 | E20182 |
Reinforced stainless steel grid, electropolished, max. loading 60 kg; from size 450 with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber | E29767 | E29767 | E29766 | E29766 | B32190 | B32190 | B32190 | B32190 |
Perforated stainless steel shelf | B00325 | B00325 | B29725 | B29725 | B00328 | B00328 | B00328 | B00328 |
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1. Please consider max. loading of chamber | - | - | - | - | B32191 | B32191 | B32191 | B32191 |
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 | E02073 | E02073 | E29726 | E29726 | E02075 | E02075 | E02075 | E02075 |
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 | - | - | - | - | - | B32763 | B32763 | B32763 |
Max. loading per slide-in drip tray (kg) | 3 | 3 | 4 | 4 | 8 | 8 | 8 | 8 |
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 | B04359 | B04359 | B29722 | B29722 | B04362 | B04362 | B04362 | B04362 |
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 | - | - | - | - | B34055 | B34055 | B34055 | B34055 |
Max. loading per bottom drip tray (kg) | 3 | 3 | 4 | 4 | 8 | 8 | 8 | 8 |
USB-Ethernet adapter | E06192 | E06192 | E06192 | E06192 | E06192 | E06192 | E06192 | E06192 |
Ethernet connection cable 5 m for computer interface | E06189 | E06189 | E06189 | E06189 | E06189 | E06189 | E06189 | E06189 |
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) | B33170 | B33170 | B33170 | B33170 | B33170 | B33170 | B33170 | B33170 |
FDA conforming software AtmoCONTROL (FDA edition). Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) | FDAQ1 | FDAQ1 | FDAQ1 | FDAQ1 | FDAQ1 | FDAQ1 | FDAQ1 | FDAQ1 |
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) | FDAQ2 | FDAQ2 | FDAQ2 | FDAQ2 | FDAQ2 | FDAQ2 | FDAQ2 | FDAQ2 |
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) | E39696 | E39696 | E39696 | E39696 | E39696 | E39696 | E39696 | E39696 |
DAkkS calibration for further temperature values according to method C (DKD-R 5-7) | E39697 | E39697 | E39697 | E39697 | E39697 | E39697 | E39697 | E39697 |
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer | D00127 | D00127 | D00127 | D00127 | D00127 | D00127 | D00127 | D00127 |
On-site IQ/OQ for a freely selectable temperature value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) | DLQ100 | DLQ100 | DLQ100 | DLQ100 | DLQ100 | DLQ100 | DLQ100 | DLQ100 |
Extension of DLQ100 by an additional freely selectable temperature value (not subject to discount) | DLQ100A | DLQ100A | DLQ100A | DLQ100A | DLQ100A | DLQ100A | DLQ100A | DLQ100A |
Individual on-site Performance Qualification (PQ) | DLQ200 | DLQ200 | DLQ200 | DLQ200 | DLQ200 | DLQ200 | DLQ200 | DLQ200 |
Maintenance ICP/ ICPeco - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) | S00315 | S00315 | S00315 | S00315 | S00315 | S00315 | S00315 | S00315 |
Maintenance contract ICP/ ICPeco - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) | S00315J | S00315J | S00315J | S00315J | S00315J | S00315J | S00315J | S00315J |
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, FR only) | S00205 | S00205 | S00205 | S00205 | S00205 | S00205 | S00205 | S00205 |
Calibration of an additional temperature value (not subject to discount) | S00215 | S00215 | S00215 | S00215 | S00215 | S00215 | S00215 | S00215 |
Individual Customizations for Specialized Applications
With Memmert m360 we are able to customize our equipment from small modifications to high-tech innovations to meet your exact requirements.