HCP150 Memmert Humidity Chamber
Former Models: HCP156
Overview
HCP 150 Memmert climate chambers guarantee the perfect atmosphere for climate and temperature tests.
Contact us for customization options and pricing.
Features
Temperature & Humidity
Control technology
Safety, Standards, & Data
Interior & Exterior
Accessories
Temperature & Humidity
Temperature Specs:
- Working temperature range without humidity:
6°C up to +90°C - Setting temperature range:
+18 to 90°C - Setting accuracy temperature:
0.1°C - Temperature:
2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
Humidity Specs:
- Humidity control:
Active microprocessor control for humidifying and dehumidifying (20 – 95 % rh), incl digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times. Humidity supply with distilled water (from an external tank) by a self-priming pump; integral bacteria block by generating hot steam, dehumidifying via sterile filter - Setting range active:
20 to 95 % rh and rh-Off - Setting accuracy humidity:
0.5 % rh
Control technology
Control Technology:
- ControlCOCKPIT:
TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays. - Language Setting:
German, English, Spanish, French, Polish, Czech, Hungarian - Adjustable Parameter:
Temperature (Celsius or Fahrenheit), relative humidity, program time, time zones, daylight savings time - Timer:
Digital backwards counter with target time setting, adjustable from 1 minute to 99 days - Function SetpointWAIT:
The process time does not start until the set temperature is reached - Calibration:
Three freely selectable temperature values
Safety & Standards
Safety:
- Temperature control:
mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature - Temperature control:
over- and under temperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, adjustable at the controller - AutoSAFETY:
additionally integrated over- and under temperature protection “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or under temperature, heating is switched off in case of overtemperature, the compressor in case of under temperature - Autodiagnostic system:
integral fault diagnostics for temperature and humidity control - Alarm:
with visual and acoustic alarm in case of over-/under temperature and under humidity, open door and empty water tank
Additional data
Electrical data
230 Volts
- 50/60 Hz
- approx. 7.8 A
115 Volts
- 50/60 Hz
- approx. 15.7 A
Certifications
Interior & Exterior
Stainless Steel Interior
- Volume:
256 l - Dimensions W x H x D in mm
w(A) x h(B) x d(C): 22" x 27.6" x 15.7" - Max. number of internals:
10 - Max. loading of chamber:
264 lbs - Max. loading per internal:
33 lbs - Interior:
Material 1.4301 (ASMTM 304), corrosion resistant
Stainless Steel
For many years exterior textured stainless steel has been the unmistakable feature of Memmert ovens, incubators, and climate chambers in laboratory and light-industrial settings. Memmert equipment exemplifies functional design in its most elegant and hygienic form, while still being scratch resistant, robust and durable.
Stainless steel is the ideal material for temperature control chambers and heating baths. It is particularly corrosion-resistant, hygienic, robust and recyclable without question.
Wherever Memmert ovens and heating baths are used, the superiority of high-quality stainless steel is undeniable in comparison to others that utilize coated sheet steel, which can corrode very quickly when in constant use.
For the outer housing of all Memmert appliances, textured stainless steel is used (rear walls are zinc-plated sheets). The inner chamber, sliding shelves/grids, housing, interior basin and accessories for every heating bath, stainless steel of class W-St. 1.4301 (ASTM 304) is used. Since aggressive substances are frequently used in the vacuum drying oven, the inner chamber and thermoshelves are made of stainless-steel W-St. 1.4404 (ASTM 316L), and the tubing is made of stainless-steel W-St. 1.4571 (ASTM 316i).
Accessories
Model sizes | 50 | 105 | 150 | 240 |
---|---|---|---|---|
Perforated stainless steel shelf | E35160 | E37418 | E37418 | E35158 |
Stainless steel grid, electropolished | E20164 | E20165 | E20165 | E43118 |
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. | ZWVR6 | ZWVR6 | ZWVR6 | ZWVR6 |
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand | ZWVR7 | ZWVR7 | ZWVR7 | ZWVR7 |
Guarantee extension by 1 year | GA3Q5 | GA3Q5 | GA3Q5 | GA3Q5 |
USB-Ethernet adapter | E06192 | E06192 | E06192 | E06192 |
Ethernet connection cable 5 m for computer interface | E06189 | E06189 | E06189 | E06189 |
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) | B33170 | B33170 | B33170 | B33170 |
Stacking set (4 pcs) for stacking of appliances of same size | B29744 | B29744 | - | - |
Stacking set (4 pcs) for stacking of appliances of same size | - | - | B42114 | - |
Stacking set (consisting of stacking corners, one connecting plate for the rear, two wall brackets) for stacking of two units of same size (size 240 only in combination with subframe B33509 or B43598) | - | - | - | B48129 |
Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used for 2 stacked units) | B33504 | B33505 | B33505 | B33506 |
Subframe (130 mm high); sizes 150/240: only in combination with the corresponding stacking sets for stacked appliances. | B33507 | B33508 | B33508 | B33509 |
Subframe, on castors (height 120 mm; stainless steel, material 1.4301) | - | - | - | B43598 |
FDA conforming software AtmoCONTROL (FDA edition). Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) | FDAQ1 | FDAQ1 | FDAQ1 | FDAQ1 |
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) | FDAQ2 | FDAQ2 | FDAQ2 | FDAQ2 |
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) | B04714 | B04714 | B04714 | B04714 |
DAkkS calibration for one (freely selectable) temperature and humidity value according to method C (DKD-R 5-7) | E48847 | E48847 | E48847 | E48847 |
DAkkS calibration for further temperature and humidity values according to method C (DKD-R 5-7) | E48848 | E48848 | E48848 | E48848 |
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer | D00124 | D00124 | D00124 | D00124 |
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring points (26 measuring points on model HPP1400) to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP and ICH). | D00136 | D00136 | D00136 | D00136 |
On-site IQ/OQ for a freely selectable temperature and humidity value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) | DLQ101 | DLQ101 | DLQ101 | DLQ101 |
Extension of DLQ101 by an additional freely selectable temperature and humidity value (not subject to discount) | DLQ101A | DLQ101A | DLQ101A | DLQ101A |
Individual on-site Performance Qualification (PQ) | DLQ200 | DLQ200 | DLQ200 | DLQ200 |
Maintenance HCP - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) | S00313 | S00313 | S00313 | S00313 |
Maintenance contract HCP - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) | S00313J | S00313J | S00313J | S00313J |
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, FR only) | S00205 | S00205 | S00205 | S00205 |
Calibration of an additional temperature value (not subject to discount) | S00215 | S00215 | S00215 | S00215 |
Calibration of one freely selectable temperature and humidity value (excluding travel costs, not subject to discount, GER, AT, FR only) | S00207 | S00207 | S00207 | S00207 |
Calibration of an additional temperature and humidity value (not subject to discount) | S00216 | S00216 | S00216 | S00216 |
Individual Customizations for Specialized Applications
With Memmert m360 we are able to customize our equipment from small modifications to high-tech innovations to meet your exact requirements.