Please enable javascript for full website functionality.

HCP150 Memmert Humidity Chamber

Former Models: HCP156

Overview

HCP 150 Memmert climate chambers guarantee the perfect atmosphere for climate and temperature tests. 

Contact us for customization options and pricing.

Features

Stainless Steel Scratch resistant, hygienic and durable.
AtmoCONTROL Create & monitor programs.
3 Year Warranty A limited 3 year warranty is included with the option to purchase an extra year.
TwinDISPLAY Twice the features of SingleDISPLAY. Monitor programs easily via Ethernet or USB.

Temperature & Humidity

Control technology

Safety, Standards, & Data

Interior & Exterior

Accessories

Temperature & Humidity

Temperature Specs:

  • Working temperature range without humidity: 
    6°C up to +90°C
  • Setting temperature range: 
    +18 to 90°C
  • Setting accuracy temperature:
    0.1°C
  • Temperature:
    2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value

Humidity Specs:

  • Humidity control: 
    Active microprocessor control for humidifying and dehumidifying (20 – 95 % rh), incl digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times. Humidity supply with distilled water (from an external tank) by a self-priming pump; integral bacteria block by generating hot steam, dehumidifying via sterile filter
  • Setting range active: 
    20 to 95 % rh and rh-Off
  • Setting accuracy humidity: 
    0.5 % rh

Control technology

Control Technology:

  • ControlCOCKPIT:
    TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays.
  • Language Setting:
    German, English, Spanish, French, Polish, Czech, Hungarian
  • Adjustable Parameter: 
    Temperature (Celsius or Fahrenheit), relative humidity, program time, time zones, daylight savings time
  • Timer: 
    Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
  • Function SetpointWAIT: 
    The process time does not start until the set temperature is reached
  • Calibration: 
    Three freely selectable temperature values

Safety & Standards

Safety:

  • Temperature control:
    mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature
  • Temperature control:
    over- and under temperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, adjustable at the controller
  • AutoSAFETY: 
    additionally integrated over- and under temperature protection “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or under temperature, heating is switched off in case of overtemperature, the compressor in case of under temperature
  • Autodiagnostic system: 
    integral fault diagnostics for temperature and humidity control
  • Alarm:
    with visual and acoustic alarm in case of over-/under temperature and under humidity, open door and empty water tank

Additional data

Electrical data

230 Volts
  • 50/60 Hz
  • approx. 7.8 A
115 Volts
  • 50/60 Hz
  • approx. 15.7 A

Certifications

CE Mark of European Economic Area VDE certified Geprufte Sicherheit certified CMET Certified EAC Certified

Interior & Exterior

Stainless Steel Interior

  • Volume:
    256 l
  • Dimensions W x H x D in mm
    w(A) x h(B) x d(C): 22" x 27.6" x 15.7"
  • Max. number of internals: 
    10
  • Max. loading of chamber: 
    264 lbs
  • Max. loading per internal: 
    33 lbs
  • Interior: 
    Material 1.4301 (ASMTM 304), corrosion resistant

Stainless Steel

For many years exterior textured stainless steel has been the unmistakable feature of Memmert ovens, incubators, and climate chambers in laboratory and light-industrial settings. Memmert equipment exemplifies functional design in its most elegant and hygienic form, while still being scratch resistant, robust and durable.

Stainless steel is the ideal material for temperature control chambers and heating baths. It is particularly corrosion-resistant, hygienic, robust and recyclable without question.

Wherever Memmert ovens and heating baths are used, the superiority of high-quality stainless steel is undeniable in comparison to others that utilize coated sheet steel, which can corrode very quickly when in constant use.

For the outer housing of all Memmert appliances, textured stainless steel is used (rear walls are zinc-plated sheets). The inner chamber, sliding shelves/grids, housing, interior basin and accessories for every heating bath, stainless steel of class W-St. 1.4301 (ASTM 304) is used. Since aggressive substances are frequently used in the vacuum drying oven, the inner chamber and thermoshelves are made of stainless-steel W-St. 1.4404 (ASTM 316L), and the tubing is made of stainless-steel W-St. 1.4571 (ASTM 316i).

Accessories

 

Model sizes50105150240
Perforated stainless steel shelf E35160 E37418 E37418 E35158
Stainless steel grid, electropolished E20164 E20165 E20165 E43118
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. ZWVR6 ZWVR6 ZWVR6 ZWVR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand ZWVR7 ZWVR7 ZWVR7 ZWVR7
Guarantee extension by 1 year GA3Q5 GA3Q5 GA3Q5 GA3Q5
USB-Ethernet adapter E06192 E06192 E06192 E06192
Ethernet connection cable 5 m for computer interface E06189 E06189 E06189 E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170 B33170 B33170 B33170
Stacking set (4 pcs) for stacking of appliances of same size B29744 B29744 - -
Stacking set (4 pcs) for stacking of appliances of same size - - B42114 -
Stacking set (consisting of stacking corners, one connecting plate for the rear, two wall brackets) for stacking of two units of same size (size 240 only in combination with subframe B33509 or B43598) - - - B48129
Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used for 2 stacked units) B33504 B33505 B33505 B33506
Subframe (130 mm high); sizes 150/240: only in combination with the corresponding stacking sets for stacked appliances. B33507 B33508 B33508 B33509
Subframe, on castors (height 120 mm; stainless steel, material 1.4301) - - - B43598
FDA conforming software AtmoCONTROL (FDA edition). Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1 FDAQ1 FDAQ1 FDAQ1
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) FDAQ2 FDAQ2 FDAQ2 FDAQ2
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) B04714 B04714 B04714 B04714
DAkkS calibration for one (freely selectable) temperature and humidity value according to method C (DKD-R 5-7) E48847 E48847 E48847 E48847
DAkkS calibration for further temperature and humidity values according to method C (DKD-R 5-7) E48848 E48848 E48848 E48848
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124 D00124 D00124 D00124
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring points (26 measuring points on model HPP1400) to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP and ICH). D00136 D00136 D00136 D00136
On-site IQ/OQ for a freely selectable temperature and humidity value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) DLQ101 DLQ101 DLQ101 DLQ101
Extension of DLQ101 by an additional freely selectable temperature and humidity value (not subject to discount) DLQ101A DLQ101A DLQ101A DLQ101A
Individual on-site Performance Qualification (PQ) DLQ200 DLQ200 DLQ200 DLQ200
Maintenance HCP - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) S00313 S00313 S00313 S00313
Maintenance contract HCP - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) S00313J S00313J S00313J S00313J
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, FR only) S00205 S00205 S00205 S00205
Calibration of an additional temperature value (not subject to discount) S00215 S00215 S00215 S00215
Calibration of one freely selectable temperature and humidity value (excluding travel costs, not subject to discount, GER, AT, FR only) S00207 S00207 S00207 S00207
Calibration of an additional temperature and humidity value (not subject to discount) S00216 S00216 S00216 S00216

 

Individual Customizations for Specialized Applications


With Memmert m360 we are able to customize our equipment from small modifications to high-tech innovations to meet your exact requirements.

Learn more about m360

Connect With Your
Regional Salesperson

VERSATILE PRODUCTS TO SERVE DEMANDING APPLICATIONS

Medical

Industrial

Electronics

Aerospace

Education

Life Science

Pharmaceuticals

Food & Beverage

Companies Served

atmocontrol instagram pdf techsupport touch twindisplay twitter phone email youtube linkedin play stainless facebook warranty mappin operation